Commit Graph
5 Commits
Author SHA1 Message Date
m-hauandHarry c390a41d82 Optimize pre-commit download (#3674)
* Fix non-local rack pickle path

Looks like a copy&paste error from/in 57742dbb.

* Optimize download

Use a partial clone, which is supported in Git since 2.18 (released
2018). The amount of actually downloaded data is roughly equal to the
size of the required files, the compression offsets the git overhead.

* Fallback for old git versions

---------

Co-authored-by: Harry <Harry@cadby.co.uk>
2025-12-28 16:48:10 +00:00
m-hau 329d9f08ae Improve ZPE Service Routers (#3389)
* Add ZPE NSR

* Add ZPE GSR

* Add ZPE BSR

* Remove monitor ports

Don't model them as proper ports, but keep them as comments.

* Use dc-terminal for dc power inputs

* Remove virtual interfaces
2025-08-15 13:15:38 +01:00
m-hau 8b3214b4b6 Fix _is_power_source in README (#3404)
Forgot that in the original PR.
2025-08-11 14:25:28 +01:00
m-hau 9e6cf8d017 Enforce component properties (#3391)
* Disable additional properties for components

It is not a global option, it needs to be set per-definition.
Enabling it produces a lot of validation errors.

* Update json schema

Add missing fields and value constraints. The `rf_role` enum is
currently not included in the `generated_schema.json` from upstream,
so I "faked" it for now by added it manually.

* Rework custom power source marker

While you could technically have a device that does PoE and serial
console on the same port, this is just one very specific scenario.
Rename the custom property from `poe` to `_is_power_source` to be more
general and better reflect its intention, and properly document it in
the json schema.
Remove the property from device types where it is false, and where it's
unneeded because power-ports exist.

* Fix power draw

In NetBox the PSU modules have a power draw, but not the module-bays you
can put them into; so remove it from those. Plus some minor corrections.

* Fix PoE

Basically fix the casing by renaming from the wrong kebab-case to the
correct snake_case.

* Turn invalid comments into description

Only device types can have `comments`, everything else is limited to
`description`. So turn all invalid comments into descriptions.

* Fix mgmt_only

Console port in NetBox don't have a `mgmt_only` property, because they
are by definition management-only.

* Fix position(s)

Device bays don't have a position, because the child devices are
completely separate and don't share any naming/numbering.

* Miscellaneous fixes

Everything that didn't fit into the prior larger error categories.
Validation now passes again.
2025-08-08 22:10:01 +01:00
m-hauandHarry 5d900ec8fb Cisco Nexus 7700 device and module types (#3321)
Co-authored-by: Harry <Harry@cadby.co.uk>
2025-08-04 14:14:06 +01:00